2.6 备份一体机管理 52XX

2.6 备份一体机管理 52XX 一、一体机操作命令2.6.1NBU进程管理查看nbu进程nbu-a:~#su–adminnbu-a.Main_Menu>Supportnbu-a.Support>Proces

大家好,又见面了,我是你们的朋友全栈君。

一、一体机操作命令

2.6.1NBU进程管理
查看nbu进程
nbu-a:~ # su – admin
nbu-a.Main_Menu> Support
nbu-a.Support> Processes
nbu-a.Processes> NetBackup Show

启动nbu进程
nbu-a:~ # su – admin
nbu-a.Main_Menu> Support
nbu-a.Support> Processes
nbu-a.Processes> NetBackup Start

停止nbu进程
nbu-a:~ # su – admin
nbu-a.Main_Menu> Support
nbu-a.Support> Processes
nbu-a.Processes> NetBackup Stop

2.6.2一体机磁盘空间监控

nbu-a:~ # /usr/openv/pdde/pdcr/bin/crcontrol –dsstat

************ Data Store statistics ************
Data storage Raw Size Used Avail Use%
69.8T 65.7T 38.4T 27.3T 59%

Number of containers : 173468
Average container size : 242735821 bytes (231.49MB)
Space allocated for containers : 42106897429278 bytes (38.30TB)
Reserved space : 4490302407680 bytes (4.08TB)
Reserved space percentage : 5.9%

Use “–dsstat 1” to get more accurate statistics
Use “–dsstat 2” to get statistics for each partition
Use “–dsstat 3” to get more accurate statistics for each partition

 

2.6.3查看主机硬件信息

nbu-a:~ # su – admin
nbu-a.Main_Menu> Monitor
nbu-a.Monitor> Hardware
nbu-a.Monitor> Hardware ShowHealth
nbu-a.Monitor> Hardware ShowHealth Appliance

2.6.4查看磁盘柜硬件信息
nbu-a:~ # su – admin
nbu-a.Main_Menu> Monitor
nbu-a.Monitor> Hardware
nbu-a.Monitor> Hardware ShowHealth
nbu-a.Monitor> Hardware ShowHealth StorageShelf

 

2.6.5收集datacollect

nbu-a:~ # su – admin
nbu-a.Main_Menu> Support
nbu-a.Support> DataCollect

All logs have been collected in /tmp/DataCollect.zip

在提示的目录下找到对应的nbsu数据包,然后使用scp或ftp客户端工具传送至PC电脑本地。

2.6.6收集nbsu

nbu-a:~ # su – admin
nbu-a.Main_Menu> Support
nbu-a.Support> NBSU Create

 

The results are located in the
/log/netbackup/nbsu/2016-01-14-15-57-31 directory…

在提示的目录下找到对应的nbsu数据包,然后使用scp或ftp客户端工具传送至PC电脑本地。

二 、一体机开关机操作

1)、停止nbu进程
nbu-a:~ # su – admin
nbu-a.Main_Menu> Support
nbu-a.Support> Processes
nbu-a.Processes> NetBackup Stop

2)停止操作系统
停止nbu进程
nbu-a:~ # init 0

3)关闭硬件设备

 <span role="heading" aria-level="2">2.6 备份一体机管理 52XX

 

三、NBU一体机登陆过程

 

字符界面登陆备份一体机xshell连接一体机,输入账户密码

 

WARNING! The remote SSH server rejected X11 forwarding request.

Last login: Fri Mar 21 18:25:34 2020 from 192.168.100.166

Master.Main_Menu> Support 

 

Master.Support> Maintenance 

<!– Maintenance Mode –!>

maintenance’s password: 

maintenance-!> /opt/Symantec/sdcssagent/IPS/sisipsoverride.sh

 

Symantec Data Center Security Server Policy Override

    Agent Version: 6.8.0 (build 309)

   Current Policy: NetBackup Appliance Prevention Policy, r160

Policy Prevention: Disabled

  Policy Override: Allowed

   Override State: Overridden 

    Override Type: Prevention Overridden Completely 

    Override User: maintenance

 Previous Comment: 

Auto re-enable in: 2 hours, 32 minutes, 49 seconds

 

Do you wish to:

 1. Re-enable the Policy.

 2. Extend the Override Time.

Choice? [1] 2

To Extend the override time, enter your login password.

Password: 

 

Choose the extend time:

Choice? [1] 6

Enter a comment. Press Enter to continue.

Please wait while the override time is extended.

The Override Time has been extended.

maintenance-!> elevate

Master:/home/maintenance # id

uid=0(root) gid=0(root) groups=0(root),1005(root)

 

四、备份带宽限制

2.7.1限制备份带宽,调整备份速度

Netbackup的限制备份带宽功能可以让你限制数据备份的带宽,从而在不影响应用运行的情况下进行数据备份。该功能仅限制备份带宽,并不影响恢复带宽。它也不影响Server的备份。
当备份启动时,NetBackup根据设定将数值传给Client,Client会根据该值控制传送给Server的速度
如果在一个子网上同时进行的备份工作增加或减少,NetBackup会动态提高或降低数据传输速度
限制备份带宽,仅适用于文件备份的策略。

配置方法1
在 /usr/openv/netbackup/bp.conf中加入下面一行:
LIMIT_BANDWIDTH = 111.112.113.1 111.112.113.50 5000
对于不同的范围的IP地址的主机,可以加多行,上面一行表示IP地址从111.112.113.1到111.112.113.50的所有主机,每个主机备份速度限定为5000Kbytes/s
配置方法2
1)通过JavaConsole进入MasterServers Properties,右侧右键点击主服务器,选择Properties…进入主服务器属性配置界面。

<span role="heading" aria-level="2">2.6 备份一体机管理 52XX

 

进入Properties窗口,左侧选择Bandwidth进入带宽限制设置。
点击Add新增一个带宽设置

<span role="heading" aria-level="2">2.6 备份一体机管理 52XX

 

上图实例限制10.10.10.200的文件备份速度为50MB/s。

# 三、NBU一体机登陆管理
字符界面登陆备份一体机xshell连接一体机,输入账户密码 WARNING! The remote SSH server rejected X11 forwarding request.Last login: Fri Mar 21 18:25:34 2020 from 192.168.100.166
Appliance  Manage master and media appliances.Exit       Log out and exit from the current shell.Manage     Manage NetBackup appliance.Monitor    Monitor NetBackup appliance activities.Network    Network Administration.Reports    Examine the running and historical state of the host.Settings   Change NetBackup appliance settings.Shell      Shell operations.Support    NetBackup Support.
### Master.Main_Menu> Support Entering NetBackup support view…

Checkpoint      Appliance Checkpoint Management.Cleanup         Clean or reset specific appliance monitoring data.Collect         Collect appliance details and transmit to Veritas.DataCollect     Gather device logs.Disk            Gather disk information.Errors          Display NetBackup errors.Exit            Log out and exit from the current shell.FactoryReset    Reset this system to factory install imageFibreTransport  Advanced settings.InfraServices   Show/control infrastructure services.iostat          Execute the iostat command.IPMI            Remote management port configuration.KillRemoteCall  Terminate running or hung remote calls on peer compute nodes.Logs            Set level, share, unshare, view, and upload debug logs.Maintenance     Launch maintenance shell.Messages        Display the messages file.NBDNA           Network traces with NBDNA tool (Select Create or Remove).Nbperfchk       Execute the disk IO or network bandwidth check.NBSU            Manage NetBackup support data files (Select Create or Remove).Processes       Show/control NetBackup and Admin Console processes.Reboot          Reboot the system.RecoverStorage  View or delete directories backed up during appliance re-image.Return          Return to the previous menu.Service         Service management.ShelfOrdering   View or reset the Expansion Storage Shelf order.Shell           Shell operations.Show            Display information.Shutdown        Power off the system.Storage         Storage data and configurationTest            Test the current status of various appliance components.

### Master.Support> Maintenance \<!– Maintenance Mode –!>maintenance’s password: \###  maintenance-!> /opt/Symantec/sdcssagent/IPS/sisipsoverride.sh
Symantec Data Center Security Server Policy Override    Agent Version: 6.8.0 (build 309)   Current Policy: NetBackup Appliance Prevention Policy, r160Policy Prevention: Disabled  Policy Override: Allowed   Override State: Overridden     Override Type: Prevention Overridden Completely     Override User: maintenance Previous Comment: Auto re-enable in: 2 hours, 32 minutes, 49 seconds
Do you wish to: 1. Re-enable the Policy. 2. Extend the Override Time.Choice? [1] 2To Extend the override time, enter your login password.Password: 
Choose the extend time: 1. 15 minutes 2. 30 minutes 3. 1 hour 4. 2 hours 5. 4 hours 6. 8 hoursChoice? [1] 6Enter a comment. Press Enter to continue.Please wait while the override time is extended.The Override Time has been extended.### maintenance-!> elevate
Master:/home/maintenance # iduid=0(root) gid=0(root) groups=0(root),1005(root)

版权声明:本文内容由互联网用户自发贡献,该文观点仅代表作者本人。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌侵权/违法违规的内容, 请联系我们举报,一经查实,本站将立刻删除。

发布者:全栈程序员-站长,转载请注明出处:https://javaforall.net/155173.html原文链接:https://javaforall.net

(0)
全栈程序员-站长的头像全栈程序员-站长


相关推荐

  • mac版pycharm使用方法_电脑管家mac版是什么意思

    mac版pycharm使用方法_电脑管家mac版是什么意思自定义模版在头部自动生成项目名称、文件所属作者、生成时间参数模版。File–>PreferencesforNewProject–>Editor–>FileandCodeTemplates–>PythonScript–>编辑完后点Apply–>OK#!/usr/bin/envpython#-*-coding…

    2022年8月26日
    2
  • 服务器地址和端口号是什么怎么看_常见服务对应的端口号

    服务器地址和端口号是什么怎么看_常见服务对应的端口号常用端口号与对应的服务以及端口关闭端口简介:本文介绍端口的概念,分类,以及如何关闭/开启一个端口21端口:21端口主要用于FTP(FileTransferProtocol,文件传输协议)服务。

    2022年8月4日
    5
  • db4o使用全解「建议收藏」

    db4o使用全解「建议收藏」db4o使用全解 db4o是一种纯对象数据库,相对于传统的关系数据库+ORM,db4o具有以下好处:1)以存对象的方式存取数据(不过你考虑一下完全以对象的方式去考虑数据的存取对传统的数据库设计思维来说是多么大的颠覆)2)无需数据库服务器,只需要一个数据文件,且dll大小仅为300多k,非常适合作为嵌入式数据库;3)提供QueryBySample,NativeQuery和S

    2022年7月21日
    9
  • 基于全卷积神经网络的图像分割方法详解(二)

    基于全卷积神经网络的图像分割方法详解(二)最近这段时间刚好忙完学业作业,抽空来总结一下前段时间的工作。前段时间一直忙于用深度学习做医学图像分割,采用的方法是FCN,也就是全卷积神经网络。全卷积神经网络是基于卷积神经网络的改进,使得输入和输出的尺寸一致,并且对每个像素点进行分类,达到图像分割的目的。下图是全卷积神经网络的流程图。其中第一行是提取特征步骤,然后2Xconv7和4Xconv7分别表示对conv7的输出进行2倍和4倍上采样…

    2022年6月19日
    34
  • javah命令详解「建议收藏」

    javah命令详解「建议收藏」概述:最近在写c++/c的一个小的项目,需要打成动态库,供java使用。就对java调用c++/c代码做了简答了解,在此做记录。jni开发第一步,就是用javah命令生成生成c\c++头文件。javah命令参数详解cmd(默认配置jdkpath)执行javah-help如下图:-d和-o这两个参数用于设置生成的C\C++头文件的指定,该两参数选项不能同时使…

    2022年9月25日
    0
  • 【Java】Thread类中的join()方法原理

    【Java】Thread类中的join()方法原理简介join()是Thread类的一个方法。根据jdk文档的定义:publicfinalvoidjoin()throwsInterruptedException:Waitsforthisthreadtodie.join()方法的作用,是等待这个线程结束;但显然,这样的定义并不清晰。个人认为”Java7ConcurrencyCookbook”的定义较为…

    2022年5月27日
    48

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注

关注全栈程序员社区公众号