mysql 隐式转换_js强制转换和隐式转换

mysql 隐式转换_js强制转换和隐式转换导读作者徐晨亮,MySQLDBA,知数堂学员。热衷于数据库优化,自动化运维及数据库周边工具开发,对MySQL源码有一定的兴趣本文建议横屏观看,效果更佳一、问题描述roo…


Jetbrains全系列IDE稳定放心使用

导读

作者徐晨亮, MySQL DBA,知数堂学员。热衷于数据库优化,自动化运维及数据库周边工具开发,对 MySQL源码有一定的兴趣

本文建议横屏观看,效果更佳


一、问题描述

root@mysqldb 22:12:  [xucl]> show create table t1\G
*************************** 1. row ***************************
       Table: t1
Create Table: CREATE TABLE `t1` (
  `id` varchar(255) DEFAULT NULL
) ENGINE=InnoDB DEFAULT CHARSET=utf8
1 row in set (0.00 sec)

root@mysqldb 22:19:  [xucl]> select * from t1;
+--------------------+
| id                 |
+--------------------+
| 204027026112927605 |
| 204027026112927603 |
| 2040270261129276   |
| 2040270261129275   |
| 100                |
| 101                |
+--------------------+
6 rows in set (0.00 sec)

奇怪的现象:

root@mysqldb 22:19:  [xucl]> select * from t1 where id=204027026112927603;
+--------------------+
| id                 |
+--------------------+
| 204027026112927605 |
| 204027026112927603 |
+--------------------+
2 rows in set (0.00 sec)

640?wx_fmt=jpeg

什么鬼,明明查的是204027026112927603,为什么204027026112927605也出来了

二、源码解释

堆栈调用关系如下所示:

640?wx_fmt=jpeg

其中JOIN::exec()是执行的入口,Arg_comparator::compare_real()是进行等值判断的函数,其定义如下

int Arg_comparator::compare_real()
{
  /*
    Fix yet another manifestation of Bug#2338. 'Volatile' will instruct
    gcc to flush double values out of 80-bit Intel FPU registers before
    performing the comparison.
  */
  volatile double val1, val2;
  val1= (*a)->val_real();
  if (!(*a)->null_value)
  {
    val2= (*b)->val_real();
    if (!(*b)->null_value)
    {
      if (set_null)
        owner->null_value= 0;
      if (val1 < val2)  return -1;
      if (val1 == val2) return 0;
      return 1;
    }
  }
  if (set_null)
    owner->null_value= 1;
  return -1;
}

比较步骤如下图所示,逐行读取t1表的id列放入val1,而常量204027026112927603存在于cache中,类型为double类型(2.0402702611292762E+17),所以到这里传值给val2后val2=2.0402702611292762E+17。

640?wx_fmt=jpeg

当扫描到第一行时,204027026112927605转成doule的值为2.0402702611292762e17,等式成立,判定为符合条件的行,继续往下扫描,同理204027026112927603也同样符合

640?wx_fmt=jpeg

如何检测string类型的数字转成doule类型是否溢出呢?这里经过测试,当数字超过16位以后,转成double类型就已经不准确了,例如20402702611292711会表示成20402702611292712(如图中val1)

640?wx_fmt=jpeg

640?wx_fmt=jpeg

MySQL string转成double的定义函数如下:

{
  char buf[DTOA_BUFF_SIZE];
  double res;
  DBUG_ASSERT(end != NULL && ((str != NULL && *end != NULL) ||
                              (str == NULL && *end == NULL)) &&
              error != NULL);

  res= my_strtod_int(str, end, error, buf, sizeof(buf));
  return (*error == 0) ? res : (res < 0 ? -DBL_MAX : DBL_MAX);
}

真正转换函数my_strtod_int位置在dtoa.c(太复杂了,简单贴个注释吧)

/*
  strtod for IEEE--arithmetic machines.
 
  This strtod returns a nearest machine number to the input decimal
  string (or sets errno to EOVERFLOW). Ties are broken by the IEEE round-even
  rule.
 
  Inspired loosely by William D. Clinger's paper "How to Read Floating
  Point Numbers Accurately" [Proc. ACM SIGPLAN '90, pp. 92-101].
 
  Modifications:
 
   1. We only require IEEE (not IEEE double-extended).
   2. We get by with floating-point arithmetic in a case that
     Clinger missed -- when we're computing d * 10^n
     for a small integer d and the integer n is not too
     much larger than 22 (the maximum integer k for which
     we can represent 10^k exactly), we may be able to
     compute (d*10^k) * 10^(e-k) with just one roundoff.
   3. Rather than a bit-at-a-time adjustment of the binary
     result in the hard case, we use floating-point
     arithmetic to determine the adjustment to within
     one bit; only in really hard cases do we need to
     compute a second residual.
   4. Because of 3., we don't need a large table of powers of 10
     for ten-to-e (just some small tables, e.g. of 10^k
     for 0 <= k <= 22).
*/

既然是这样,我们测试下没有溢出的案例

root@mysqldb 23:30:  [xucl]> select * from t1 where id=2040270261129276;
+------------------+
| id               |
+------------------+
| 2040270261129276 |
+------------------+
1 row in set (0.00 sec)

root@mysqldb 23:30:  [xucl]> select * from t1 where id=101;
+------+
| id   |
+------+
| 101  |
+------+
1 row in set (0.00 sec)

结果符合预期,而在本例中,正确的写法应当是

root@mysqldb 22:19:  [xucl]> select * from t1 where id='204027026112927603';
+--------------------+
| id                 |
+--------------------+
| 204027026112927603 |
+--------------------+
1 row in set (0.01 sec)

三、结论

  1. 避免发生隐式类型转换,隐式转换的类型主要有字段类型不一致、in参数包含多个类型、字符集类型或校对规则不一致等

  2. 隐式类型转换可能导致无法使用索引、查询结果不准确等,因此在使用时必须仔细甄别

  3. 数字类型的建议在字段定义时就定义为int或者bigint,表关联时关联字段必须保持类型、字符集、校对规则都一致

  4. 最后贴一下官网对于隐式类型转换的说明吧

1、If one or both arguments are NULL, the result of the comparison is NULL, except for the NULL-safe
<=> equality comparison operator. For NULL <=> NULL, the result is true. No conversion is needed.
2、If both arguments in a comparison operation are strings, they are compared as strings.
3、If both arguments are integers, they are compared as integers.
4、Hexadecimal values are treated as binary strings if not compared to a number.
5、If one of the arguments is a TIMESTAMP or DATETIME column and the other argument is a
constant, the constant is converted to a timestamp before the comparison is performed. This is
done to be more ODBC-friendly. This is not done for the arguments to IN(). To be safe, always
use complete datetime, date, or time strings when doing comparisons. For example, to achieve best
results when using BETWEEN with date or time values, use CAST() to explicitly convert the values to
the desired data type.
A single-row subquery from a table or tables is not considered a constant. For example, if a subquery
returns an integer to be compared to a DATETIME value, the comparison is done as two integers.
The integer is not converted to a temporal value. To compare the operands as DATETIME values,
use CAST() to explicitly convert the subquery value to DATETIME.
6、If one of the arguments is a decimal value, comparison depends on the other argument. The
arguments are compared as decimal values if the other argument is a decimal or integer value, or as
floating-point values if the other argument is a floating-point value.
7、In all other cases, the arguments are compared as floating-point (real) numbers.

参考文章

1、聊聊 隐式转换

2、Type Conversion in Expression Evaluation:https://dev.mysql.com/doc/refman/8.0/en/type-conversion.html

感谢八怪的友情指导,想学习更多源码内容,强烈推荐一下八怪的专栏《深入理解MySQL主从原理》

END


点击下图小程序订阅

《深入理解MySQL主从原理32讲》专栏

可了解更多八怪技术文章

640?wx_fmt=png

640?wx_fmt=png

640?wx_fmt=gif

扫码加入MySQL技术Q群

(群号:793818397)

   

版权声明:本文内容由互联网用户自发贡献,该文观点仅代表作者本人。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌侵权/违法违规的内容, 请发送邮件至 举报,一经查实,本站将立刻删除。

发布者:全栈程序员-站长,转载请注明出处:https://javaforall.net/183035.html原文链接:https://javaforall.net

赞 (0)
全栈程序员-站长的头像全栈程序员-站长


相关推荐

  • Vim复制粘贴_vim复制粘贴命令

    Vim复制粘贴_vim复制粘贴命令原文地址:http://lsong17.spaces.live.com/blog/cns!556C21919D77FB59!603.entry内容:用vim这么久了,始终也不知道怎么在vim中使用系统粘贴板,通常要在网上复制一段代码都是先gedit打开文件,中键粘贴后关闭,然后再用vim打开编辑,真的不爽;上次论坛上有人问到了怎么在vim中使用系统粘贴板,印象里回复很多,有好几

    2022年9月22日
  • 调用usb摄像头_usb监控

    调用usb摄像头_usb监控在使用DirectShow控制USB摄像头的技术方面,需要做几件准备工作:1、安装DirectShowSDK,这个比较繁琐,具体可以网上搜索。2、配置开发工具的路径,如VS2008的相关包含的路径设置3、网上有示例代码,我的资源也上传了一个示例代码。主要对代码中可能遇到的问题进行总结:一般实现功能,包含两个,一个是实时预览,一个是控制拍摄一张图像。问题就是,这两个功能单

    2022年8月31日
  • Jenkins详细教程

    Jenkins详细教程大纲  1.背景  在实际开发中,我们经常要一边开发一边测试,当然这里说的测试并不是程序员对自己代码的单元测试,而是同组程序员将代码提交后,由测试人员测试;  或者前后端分离后,经常会修改接口,然后重新部署;  这些情况都会涉及到频繁的打包部署;  手动打包常规步骤:  1.提交代码  2.问一下同组小伙伴有没有要提交的代码  3.拉取代码并打包(war包,或者jar包)  4.上传到Linux服务器  5.查看当前程序是否在运行  6.关闭当前程序  .

    2022年5月15日
  • sqlmap怎么安装_sqlmapchik

    sqlmap怎么安装_sqlmapchik一前提需要安装python2,可以看“python2下载与安装”二下载官网下载三安装将下载的sqlmap.zip解压到文件夹sqlmap中,并拷贝到Python安装路径下四配

    2022年8月2日
  • 如何关闭或启动mysql服务器_MySQL运行

    如何关闭或启动mysql服务器_MySQL运行方法一:通过命令行开启\关闭服务第一步点击开始菜单,找到cmd,以管理员身份运行。第二步在命令行里面输入“netstopmysql”,按回车键,就停止了mysql服务,如下图所示:第三步在命令行输入“netstartmysql”,接着按回车键,开启mysql服务,如下图所示:END方法二:通过电脑服务开启/关闭第一步最开始右键计算机,选择“管理”,如下图所示:第二步进去管理之后,选择服务和…

    2022年10月25日
  • Intellij IDEA快捷键大全(超详细)

    Intellij IDEA快捷键大全(超详细)IntellijIDEA快捷键大全(超详细)

    2022年5月15日

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注

关注全栈程序员社区公众号